WOLF COOKTOP VENTILATION
95
42" (1067)
47
1
/16" (1195)
MAXIMUM
HEIGHT OF HOOD
33
9
/16" (853)
MINIMUM
HEIGHT OF HOOD
27" (686)
LOCATION OF ELECTRICAL
ON CEILING THROUGH
TOP OF HOOD
8' TO 9'
(2.4 m – 2.7 m)
FLOOR TO
CEILING HEIGHT
24" TO 30"*
(610 – 762)
TO
COUNTERTOP
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling
will allow for a maximum height above the countertop of 26
7
/
16
" (672).
33
9
/16" TO 47
1
/16"
(853 – 1195)
OVERALL HEIGHT
42" (1067)
OVERALL WIDTH
18"
(457)
12"
(305)
27" (686)
OVERALL DEPTH
19
5
/16"
(491)
5"min
(127)
9
1
/4"
(235)
1
9
/16"
(40)
OVERALL DIMENSIONS
Model IH4227
INSTALLATION SPECIFICATIONS
Model IH4227
SPECIFICATIONS
Model IH4227
Overall Width 42" (1067)
Overall Height 9
1
/4" (235)
(excluding chimney)
Overall Height 33
9
/16" (853)
(including chimney)
Maximum Height 47
1
/16" (1195)
(full extension)
Overall Depth 27" (686)
Bottom of Hood
to Countertop 24" (610) to 30" (762)
Duct Size 8" (203) Round
Discharge Vertical
Internal Blowers* 600 or 900 CFM
In-Line Blowers* 600 or 1100 CFM
Remote Blowers* 600, 900, 1200 or
1500 CFM
Electrical Supply 110/120 V AC, 60 Hz
15 amp circuit
Shipping Weight 110 lbs (50 kg)
(shell only)
*Blower options vary with the cooking
surface. Refer to the cooktop ventilation
recommendations on pages 115–116.
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.