WOLF PRO VENTILATION
104
ELECTRICAL REQUIREMENTS
Wolf Pro wall and island hoods require a
separate, grounded 120 V AC, 60 Hz power
supply. The service should have its own 15 amp
circuit breaker. Placement of the electrical supply
is not critical, as long as you provide enough
120 V AC power cable to make your electrical
connections. Note that for some wall hoods,
placement of the electrical supply will differ
between vertical and horizontal discharge loca-
tions. Refer to pages 111–114 for blower and
ducting considerations to determine discharge
location.
Locate electrical within the shaded area shown
in the Installation Specifications illustration for
your model.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
PLANNING INFORMATION
Pro low-profile wall hoods are available in
30" (762), 36" (914), 42" (1067) and 48" (1219)
widths.
Pro 24" (610) deep wall hoods are available in
30" (762), 36" (914), 42" (1067), 48" (1219),
54" (1372), 60" (1524) and 66" (1676) widths.
Pro 27" (686) deep wall hoods are available in
30" (762), 36" (914), 42" (1067), 48" (1219),
54" (1372), 60" (1524) and 66" (1676) widths.
Pro wall chimney hoods are available in 36"
(914), 42" (1067), 48" (1219) and 54" (1372)
widths.
Pro island hoods are available in 36" (914),
42" (1067), 54" (1372) and 66" (1676) widths.
IMPORTANT NOTE: For optimal performance in
wall hood applications, a Pro 27" (686) deep wall
hood is recommended for use with ranges and
rangetops that contain a charbroiler or griddle.
Specifications on the following pages provide
overall dimensions, blower and ducting consider-
ations, and installation specifics for Pro wall and
island hoods. We have minimized the informa-
tion contained in the illustrations, concentrating
on the critical information you need to plan your
installation. Also refer to the Pro ventilation
recommendations on pages 117–120.
The overall dimensions illustrations include the
optional rail dimensions. Overall width, height
and depth dimensions will remain the same if a
decorative rail is not to be used.
Pro wall hoods should be at least as wide as
the cooking surface; an overlap of 3" (76) on
either side is recommended. Island hoods should
always be larger than the cooking surface by a
minimum of 3" (76) on each side.
Installation of all Pro wall and island hoods
should be 30" (762) to 36" (914) from the
bottom of the hood to the countertop.
Optional classic stainless steel duct covers are
available in heights of 6" (152), 12" (305), 18"
(457) and 24" (610) for all Pro wall and island
hoods.
ACCESSORIES
Optional accessories
are available
through your Wolf
dealer. To obtain
local dealer
information, visit
the Showroom
Locator section of
our website,
wolfappliance.com.