Wolf MW24 Specifications Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
WOLF ELECTRIC COOKTOPS
47
2"*min (51)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
18"
(457)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
39" (991)
RECOMMENDED CABINET WIDTH
36"min (914)
36-INCH OVEN OPENING
SEE COUNTERTOP
CUT-OUT BELOW
13" max
(330)
24"min
(610)
SEE COUNTERTOP
CUT-OUT BELOW
4"min (102)
E
10"
(254)
4"min (102)
TO OVEN
OPENING
3
1
/2" (89)
4
1
/2" (114)
21"
(533)
OVERALL
DEPTH
36" (914)
OVERALL WIDTH
5
1
/2" (140)4
1
/4" (108)
CONDUIT
OVERALL DIMENSIONS
New Model CT36EU
INSTALLATION SPECIFICATIONS
New Model CT36EU
Countertop Cut-Out Dimensions
SPECIFICATIONS
New Model CT36EU
Overall Width 36" (914)
Overall Height 4
1
/4" (108)
Overall Depth 21" (533)
Heating Elements Four
Temperature Zones Five
Max Element Power
Triple 1050 / 2200 / 2700 W
Dual 700 / 2200 W
Singles 1200 W and (2) 1800 W
Singles with Bridge 4400 W
Cabinet Width 39" (991) rec
36" (914) min
Cabinet Depth 22
3
/4" (578) min
Height Clearance 4
1
/2" (114) min
Cut-Out Width 34
3
/8" (873)
Cut-Out Depth 19
3
/8" (492)
Electrical Supply 240 V AC/ 60 Hz / 50 amp
208 V AC/ 60 Hz / 40 amp
Conduit 4' (1.2 m) flexible 3-wire
Electrical Rating 10.5 kW at 240 V
7.9 kW at 208 V
Shipping Weight 60 lbs (27 kg)
The outer diameter of the heating elements are
12" (305), 9" (229), two 8" (203) and 6
1
/
2
" (165).
The bridge with elements is 8" (203) x 17" (432).
IMPORTANT NOTE: A minimum height clearance
of 6
1
/
4
" (159) is required between countertop and
any combustible surface directly below cooktop.
INSTALLATION OPTIONS
The Model CT36EU unframed electric cooktop
can be mounted flush with the top of the
countertop or as a frameless installation
sitting on top of the countertop surface. In
either installation the cooktop cut-out dimen-
sions are the same. If mounted flush with the
countertop, a recessed area surrounding the
cooktop cut-out is required.
IMPORTANT NOTE: Flush mount installations
are intended for granite, solid surface or stone
countertop surfaces only. If the cooktop is to
be mounted flush with the countertop, fabrica-
tion of the recessed area must take place
before the countertop installation. A template
of the countertop cut-out will be provided with
the cooktop for fabrication purposes.
A Wolf 36" (914) L Series single oven may be
installed below the Model CT36EU. For this
installation, unless you are using cabinets
deeper than 24" (610), it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven. A 30" (762)
L Series or E Series single oven may also be
installed below the Model CT36EU.
When a 36" (914) L Series oven is installed
below a cooktop, it is recommended that the
rough opening for the oven be 7
3
/4" (197) from
the floor to ease use of the oven door.
36
1
/8"** (918)
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
34
3
/8" (873)
COOKTOP CUT-OUT WIDTH
1
5
/16" (33)
RADIUS
FRONT OF COUNTERTOP
2
7
/16" (62)
19
3
/8" (492)
COOKTOP
CUT-OUT DEPTH
1
9
/16" (40)
21
1
/8"** (537)
RECESSED AREA
FOR FLUSH MOUNT
INSTALLATION ONLY
7
/16" (11) RADIUS
**Minimum dimension, but may be exceeded by up to
1
/
8
" (3).
RECESSED AREA FOR
FLUSH MOUNT INSTALLATION ONLY
5
/16"
(
8
)
7
/8"
(22) max
COUNTERTOP
PROFILE
2"* (51)
Unit dimensions may vary to ±
1
/
8
" (3).
IMPORTANT NOTE: For flush mount applications,
it is recommended that you measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.
Available November 2007