WOLF GAS RANGES
79
PLANNING INFORMATION
Wolf gas ranges come in 30" (762), 36" (914),
48" (1219) and 60" (1524) widths. Specifications
on the following pages provide overall dimen-
sions, finished rough opening dimensions and
installation specifics for each size of gas range.
We have minimized the information contained
in the illustrations, concentrating on the critical
information you need to plan your installation.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf gas
range to avoid fires or damage to adjacent
cabinetry or kitchen equipment. Please follow
the minimum clearances established in the
finished rough opening dimensions. Refer to
specifications on the following pages for your
model.
It is recommended that you use a Wolf Pro
ventilation hood or hood liner with the Wolf gas
range. Refer to pages 102–114 for Pro ventilation
specifications.
ELECTRICAL | GAS REQUIREMENTS
The Wolf gas range requires a 110/120 V AC,
50/60 Hz electrical supply to operate the elec-
tronic ignition system. The power supply cord is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Locate electrical and gas supply within the
shaded area shown in the Installation
Specifications illustration for your model.
Wolf gas ranges are designed to operate on
natural gas at 5" (12.5 mb) WC (water column)
pressure or LP (propane) gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure to
the regulator should never exceed 14" (34.9 mb)
WC, .5 psi (3.5 kPa).
Wolf recommends the use of a
1
/2" (13) I.D.
commercial-type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be
3
/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range
in an accessible location.
You must follow all National Electrical Code and
gas regulations. In addition, be aware of local
codes and ordinances when installing your
services.
HIGH ALTITUDE
The Wolf gas range
functions up to
6,000' (1828 m) in
altitude without any
adjustment. If the
installation is above
6,000' (1828 m),
contact your Wolf
dealer.
BURNER RATING
Gas Ranges
Surface Burners 16,000 Btu/hr
(4.7 kW) with
500 Btu/hr (.1 kW)
delivered at simmer
Infrared Charbroiler 16,000 Btu/hr
(4.7 kW)
Infrared Griddle 18,000 Btu/hr
(5.3 kW)
Infrared Double (2) 18,000 Btu/hr
Griddle (5.3 kW)
French Top 15,000 Btu/hr
(4.4 kW)
Oven Burner (Bake) 30,000 Btu/hr
(8.8 kW)
Infrared Oven Broiler 18,000 Btu/hr
(5.3 kW)
Refer to the specific model requirements