111
BLOWER CONSIDERATIONS
All Pro ventilation hoods and hood liners are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are avail-
able. Remote blowers can be mounted on the
roof or an exterior wall.
The blower assemblies are quite varied, and
depending on the amount of air you want to
move and the length of the duct run, you have
many options.
A straight, short duct run with a limited number
of elbows and transitions will allow the ventila-
tion hood to perform most efficiently. Pro
ventilation hoods and hood liners will operate
most efficiently when ductwork does not exceed
50' (15 m) in length.
DUCTWORK INSTALLATION
THROUGH ROOF
22" (559)
DEPTH OF HOOD
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
17
3
/4"W x 4
1
/4"D TO 10" ROUND
9
3
/8"H (INCLUDING FLANGES)
ACCESSORY TRANSITION
FOR IN-LINE OR
REMOTE BLOWER
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
10" (254)
HEIGHT OF HOOD
WALL HOOD
ROOF CAP OR REMOTE BLOWER
NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH
IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE.
DUCTWORK INSTALLATION
THROUGH ROOF
24" (610)
DEPTH OF HOOD
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
VERTICAL DISCHARGE
TRANSITION
22
1
/4"W x 9"D TO 10" ROUND
10"H (INCLUDING FLANGES)
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
18" (457)
HEIGHT OF HOOD
WALL HOOD
A remote mounted blower will minimize the
amount of blower noise, but will not eliminate
the noise completely.
IMPORTANT NOTE: Install these ventilation
hoods and hood liners only with a Wolf blower.
Refer to the Pro ventilation recommendations on
pages 117–120.
DUCTING CONSIDERATIONS
Pro Low-Profile Wall Hoods
(Refer to the following page for additional ducting considerations.)
Pro 24" (610) Deep Wall Hoods
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
Page view 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 119 120

Comments to this Manuals

No comments