Wolf PW482210 Specifications Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
Do not remove the control knob bezel to
access hood wiring; this will damage the
bezel assembly.
Location of electrical box
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
ELECTRICAL WIRING
This ventilation hood must be properly
grounded. This unit should be installed by
a qualified electrician in accordance with
all applicable national and local electrical
codes.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag,
to the service panel.
Follow these instructions to install wiring for
all Wolf Pro wall hoods:
Run a 120 V AC, 15 amp circuit power cable
from the service panel to the electrical box
on the back plate.
Run the conduit connector through the
holes in the back plate. Refer to the illustra-
tion below for the location of the electrical
box.
Insert the conduit through the hole on top
of the back plate to the electrical box.
Remove the electrical box cover from the
back plate. Connect black wire to power
supply black wire, white wire to power
supply white wire and green wire to green
wire or bare wire.
Place all wiring connections inside the
electrical box and reinstall on the back plate
in the upper right-hand corner. Make sure
that the wires are secure and that no wires
are pinched between the cover and box.