Wolf IDF606CG Specifications Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
36
WOLF DUAL FUEL RANGES
PLANNING INFORMATION
Wolf dual fuel ranges come in 914 mm,
1219 mm and 1524 mm widths. Specifications
on the following pages provide overall dimen-
sions, finished rough opening dimensions and
installation specifics for each size of dual fuel
range. We have minimized the information
contained in the illustrations, concentrating on
the critical information you need to plan your
installation.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf dual
fuel range to avoid fires or damage to adjacent
cabinetry or kitchen equipment. Please follow
the minimum clearances established in the
finished rough opening dimensions. Refer to
specifications on the following pages for your
model.
ELECTRICAL | GAS REQUIREMENTS
Specifications on the following pages provide
electrical and gas requirements for each size
of dual fuel range.
Locate electrical and gas supply within the
shaded area shown in the Installation Specifica-
tions illustration for your model.
International (I) models come with a factory
installed transformer and require a 220-240 V
AC, 50/60 Hz electrical supply, fused at the
correct rating for the unit. The appropriate elec-
trical connection must be provided in accordance
with local requirements.
Wolf dual fuel ranges are designed to operate on
natural gas at 12.5 mb WC (water column)
pressure or LP (propane) gas at 25 mb WC
pressure. The minimum line pressure for natural
gas is 17.5 mb WC and 27.4 mb WC for LP gas.
The maximum gas supply pressure to the regula-
tor should never exceed 34.9 mb WC; 3.5 kPa.
Wolf recommends the use of a 13 mm I.D.
commercial-type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 19 mm minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range
in an accessible location.
You must follow all local codes and ordinances
when installing your services.
BURNER RATING
Dual Fuel Ranges
Surface Burners 4.4 kW with .3 kW
delivered at simmer
(1) 2.7 kW with .1 kW
delivered at simmer
Infrared Charbroiler 4.7 kW
Infrared Griddle
Natural Gas 4.4 kW
LP Gas 3.8 kW
French Top 4.4 kW
Refer to the specific model requirements
for risers in non-island installations.
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 71 72

Comments to this Manuals

No comments