Outdoor Grill Installation 12
LP Gas Installations
PORTABLE LP CONNECTION
One of the many features of the Wolf grill cart is the
pull-out shelf for easy access to the LP gas cylinder. It is
designed to hold a 20-lb (5 gallon capacity) LP gas
cylinder.
1) To install the LP gas cylinder, pull out the shelf and
place the cylinder on it.
2) Check to ensure that the gas valve on top of the
cylinder is closed.
3) Connect the LP gas regulator to the cylinder and
hand-tighten only. Open the cylinder valve. Check for
leaks according to the gas leak testing procedure on
page 13.
4) Tighten the thumb screw to secure the cylinder to the
shelf.
Always check for gas leaks after changing the LP gas
cylinder.
Do not place more than one LP gas cylinder in an
enclosure at one time.
Grill cart pull-out shelf.
LP GAS CONNECTION
Install the pressure regulator and hose assembly supplied
with the outdoor product as shown in the illustrations
below. Connect the
3
/8" flare end of the hose to the unit
coupling using a
3
/4" open wrench. Do not apply pipe
sealant to the
3
/8" flare connection. Connect the regulator
to the LP cylinder hand-tighten, do not use a wrench.
LP GAS
CYLINDER
REGULATOR
GRILL
COUPLING
VENT
VENT
HOSE
ASSEMBLY
LP gas connection. LP gas regulator.
LP GAS
CYLINDER
TO GRILL
VENT
REGULATOR
COUPLING NUT
The LP pressure regulator and hose supplied with the
outdoor product must be used without alteration.