Pro Wall Hood Installation 21
wolfappliance.com/specs
In-Line and Remote Blowers
BLOWER INSTALLATION
IMPORTANT NOTE:
Refer to specific installation instruc-
tions provided with each blower assembly for additional
mounting and wiring instructions.
IMPORTANT NOTE: Use wire connectors or wire nuts
approved by UL or C/UL.
Follow specific wiring instructions provided with each
blower. Black (L1) to black, white (neutral) to white, or
white to blue, or white to brown (depending on model)
and green to grounding screw. Run ROMEX cable to
the hood.
Insert 6" (152) of ROMEX cable through the knockout
opening and into the electrical box on the back plate of
the hood. Secure the cable to the electrical box with an
appropriate connector.
Locate the cord assembly provided with the blower.
The cord assembly has two leads, black (L1) and white
(neutral). Connect these leads to the leads from the
blower, black to black and white to white.
Connect all green and bare wires together to the
ground screw in the electrical box.
Plug the cord assembly into the receptacle located
near the center of the hood shell. Refer to the illustra-
tion below. Use the clips on the interior of the hood to
secure excess power cord.
Reinstall the electrical box cover and screws in the
upper right-hand corner of the hood. Make sure all
wires are secure and that no wires are pinched
between the cover and box.
IMPORTANT NOTE: Before turning the power on to the
ventilation hood, make sure the blower is off.
When making electrical connections, make sure the
electrical power is turned off at the power source or
circuit breaker before proceeding.
BLOWER
RECEPTACLE(S)
Location of receptacle(s).