Electrical Requirements
IMPORTANT NOTE: U
nless you are using cabinets deeper
than 24" (610) for a standard installation or 25" (635) for a
flush inset installation, it is recommended that the electri-
cal supply for the oven be placed in an adjacent cabinet
within reach of the conduit. Choose the electrical location
shown in the illustrations on the following pages that best
suits your installation.
L SERIES SINGLE OVENS
Power supply: 240 / 208 V AC, 60 Hz with 30 amp
service.
Maximum connected load: 5.1 kW.
Total amps: 21 amps.
Supply wire minimum size: L1, L2 and ground
10 AWG.
L SERIES DOUBLE OVEN
Power supply: 240 / 208 V AC, 60 Hz with 50 amp
service.
Maximum connected load: 8.9 kW.
Total amps: 37 amps.
Supply wire minimum size: L1, L2 and ground
10 AWG.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and
ordinances when installing your service.
IMPORTANT NOTE: Performance may be compromised if
the electrical supply is less than 240 volts.
L Series Oven Specifications 7
wolfappliance.com/specs
T
he L series oven is provided with a conduit consisting of
two insulated hot lead conductors, one insulated neutral
conductor, and one uninsulated ground conductor. The
wiring diagram covering the control circuit is located on
the top of the L series oven in a sealed plastic bag.
UL installations: Attach the conductors to the residence
wiring in accordance with National Electrical Codes and all
state, municipal and local codes.
CSA installations: Attach the conductors to the electrical
box provided. Then connect the residence wiring to the
electrical box in accordance with all national, provincial
and local codes.
The complete appliance must be properly grounded at
all times when electrical power is applied.
Grounding through the neutral conductor is prohibited
for new branch-circuit installations (1996 NEC); mobile
homes and recreational vehicles, or where local codes
prohibit grounding through the neutral conductor.
If aluminum house supply wiring is utilized, splice the
appliance copper wire to the aluminum house wiring
using special connectors design and agency certified
for joining copper and aluminum. Follow the connector
manufacturer's recommended procedure carefully.
Improper connection can result in a fire hazard.